COLONRI I & II

(NRI, Czech Republic)
The natural convectional loops in the NRI, CZ, were designed for short/medium-term corrosion testing in liquid Pb-Bi and Pb (respectively).


Operation fluid PbBi
Temperature
Max T between
the two test sections
Flow rate
Number of test sections
Test section diameter
Total electric power
LBE purity
OCS
(Oxygen Control System)
Loop Material
Max 550°C
150°C
Max 2 cm/s
2
2,5 cm
4 kW
99,5%
Yes
AISI 321

 

COLONRI II technical specifications

Operation fluid Pb
Temperature
Max T between
the two test sections
Flow rate
Number of test sections
Test section diameter
Total electric power
Pb purity
OCS
(Oxygen Control System)
Loop Material
Max 600°C
150°C
Max 2 cm/s
2
2,5 cm
5 kW
99,5%
Yes
AISI 321

COLNRI I & II in their hall

the hall

the loop


oxygen control system